NP2 Specifications

 

Rear Panel DIP Switch selections

 

Relay 1

  Northstar Controls Inductive Loop Vehicle Detector, Detectors - NP2  Page 1Northstar Controls Inductive Loop Vehicle Detector, Detectors - NP2  Page 1Inductive Loop Detectors / Preformed Inductive Loops

Extend – switch 1 is for extending the detector output after the vehicle has left the loop.  Switch 1 in the OFF position provides no extension.  Switch 1 in the ON position provides a 5 second extension once the vehicle leaves the loop.  This extension applies to relay 1 only.

 

Delay – switch 2 is for providing a 2 second delay, Detector will ignore the vehicle until the vehicle has been present over the loop for 2 seconds.  Switch 2 in the OFF position provides no delay.  Switch 2 in the ON position provides for the 2-second delay.  This delay applies to relay 1 only.

 

Presence Time – switch 3 provides for either a 1 hour presence or permanent presence.  Switch 3 in the OFF position provides for 1 hour of presence.  Switch 3 in the ON position provides for permanent presence.  The above presence settings apply to relay 1 only.  (Other options are available).

 

Relay 2

 

Pulse Length – switch 4 provides for either a 250mS pulse length or a 500mS pulse length.  Switch 4 in the OFF position provides a 250mS (standard) pulse length.  Switch 4 in the ON position provides a 500mS pulse length.

 

Operating Mode – switch 5 and switch 6 determine the operating   mode for Relay 2. The four modes are as follows:                

 

Switch 5 and switch 6 OFF provides pulse-on-entry.

Switch 5 ON & switch 6 OFF provides pulse-on-leaving.

Switch 5 OFF & switch 6 ON provides for presence.

Switch 5 and switch 6 ON provides a fault output.

 

Front Panel Selections

 

Sensitivity – controlled by front panel rotary switch.

·          0 = Low sensitivity

·          9 = High sensitivity

Medium sensitivity is used for most applications; this is a setting of 4 or 5.  Always use the lowest sensitivity setting that detects the desired vehicles.

 

Frequency – four separate settings controlled by front panel DIP switches. 

·          2+1 = High

·          2+0 = Medium High

·          1+0 = Medium Low

·          0+0 = Low

 

Reset – front panel reset performs a hard reset of the detector.

Factory Settings:

Sensitivity Boost – automatic during detect except in the

 

highest sensitivity setting (9).

·          Set to HI frequency

 

·          Set to Medium sensitivity (5)

Factory Options:

·          Extend/Delay in the OFF position

      Presence lengths of 15, 30, 60 minutes or permanent.

·          Presence time set to 1 hour

      Pulse lengths of 250mS, 500mS, 1, 2 or 4 seconds.

·          Pulse length set to 250msec

      Extend times of 0, 2, 5 or 10 seconds.

·          Relay 1 = fail-safe

      Delay times of 0, 1, 2 or 4 seconds.

·          Relay 2 = fail-secure

      Relay 1 fail-safe or fail-secure.

 

      Relay 2 fail-safe or fail-secure.

Relay Output Rating: 7A 277VAC/30VDC.

Note: Bold  / Italics indicates standard configuration.

 

Connector 11Pin Amphenol

Power: 240 VAC, 120 VAC, 24 VAC, 24 VDC or 12 VDC.

Pin #

Function

Color

            (70mA DC or 1W AC)

1

Power (+)

Black

 

2

Power (-)

White

Inductance Range: 20uH to 1500uH.

3

Relay 2 N.O.

Orange

 

4

Ground

Green

Temperature Range:  -30 F to +180 F.

5

Relay 1 Com

Yellow

 

6

Relay 1 N.O.

Blue

Lead-In Length: up to 2500 ft. with proper lead-in and loop.

7

Loop

Gray

 

8

Loop

Brown

Mechanical:  1 3/8”w X 3 3/32”h X 3 ½”l.

9

Relay 2 Com

Red

 

10

Relay 1 N.C.

White/Blk

Weight:  8 oz.

11

Relay 2 N.C.

White/Red

 

Supply Voltage – incorrect voltage supplied to the unit will

Note:  The above connection is shown with correct power supplied and no vehicle present.

not result in damage, the unit will simply not operate until

correct voltage is supplied.  No fuses need to be reset.  

 

Northstar Controls L.L.C. warrants this product against defects in manufacturing and workmanship for one year from date of shipment from the Northstar Controls L.L.C. factory.

Indicators – front panel indicators include:

      Power – Green, solid with correct power supplied.

      Relay 1 – Red, solid during detect.

      Relay 2 – Red, solid during detect.

*Specifications are subject to change without notice.

      Fault – Yellow, solid during current fault, flashing for

                   historical fault.

  L NP2-Rev A

• Home • Ordering • Company Information • Index Page 1 • Index Page 2 • Index-Page 3 • Reference • Request Product Information •

Model Ordering Information

Unit Voltage

Part #

240 VAC

NP2-240AC

120 VAC

NP2-120AC

24 VAC

NP2-24AC

**24 VAC/DC** **NP2-24AC/DC**

24 VDC

NP2-24DC

12 VDC

NP2-12DC

 

 

 

 

 

 

 

 

 

 

 

 

 