DLS-1 Technical Data Sheet

For Pro-Seal 6006 & 6006EX

The proportion of catalyst to sealer is not very critical in obtaining a complete cure. The quantity of catalyst can be adjusted depending on climatic conditions. Use less catalyst in hot weather and more catalyst in cold weather. Each gallon of Pro-Seal is supplied with two (2) 1 ounce tubes of catalyst. Extra catalyst can be purchased separately. Use the chart below to determine the amount of catalyst to use.

          Curing Time Matrix

                  N/R=Not Recommended                       Ambient Temperature in °F

Tube(s) 30°- 45° 45°- 55° 55°- 65°

65°- 75°

75°- 80° 80°- 90° +90°
Per Gallon Time in Minuets
1

N/R

 N/R

  N/R

  N/R

 N/R

 N/R

12-18

2

N/R

 30-35

 25-30

  20-25

15-20

10-15

Under 10

3 20-25 15-20 10-15    7-10  N/R  N/R N/R
Note: To thicken Pro-Seal for use on steep inclines dry sand may be added during the mixing process. Dry sand may be spread on top of Pro-Seal to make it instantly tack free. Sand is especially helpful for lead-ins across open lanes of traffic.
Use the coverage chart below to calculate the fill rate per gallon of Pro-Seal in various size saw cuts slots.

6006 Sealer Fill Matrix

Saw Cut

Width

Depth

3/16"

1/4"

5/16"

3/8"

1/2"

1"

100'

80'

66'

53'

40'

1 1/2"

75'

53'

45'

36'

27'

2"

50'

40'

33'

26'

20'

3"

36'

27'

23'

18'

14'

• Home • Ordering • Company Information • Index Page 1 • Index Page 2 • Index-Page 3 • Reference • Request Product Information •

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pro-Seal 6006, Page 2

LIS, Inc. - Pro-Seal 6006 & 6006EX Inductive Loop Sealant, Sealer Data SheetPro-Seal 6006, Page 1

LIS, Inc. - Pro-Seal 6006 & 6006EX Inductive Loop Sealant, Sealer Data Sheet

Pro-Seal 6006, Page 1

Pro-Seal 6006, Page 2

 

 

 

 

 

 

PDF Version