Model AX Series
Specifications
Single Channel Inductive Loop Vehicle Detectors
Loop Frequency:
Four frequencies (normally in the range of
20 to 100 kHz) are dip switch selectable from the front panel
Reset:
Changing any dip switch position (except SW 1 & SW 2: frequency selection) will
reset the detector. After changing the Frequency selection switches, the
detector will require a RESET. Reset will clear the loop fault memory.
Sensitivity:
Vehicle detection results when a negative change
in loop inductance (ΔL/L) exceeds the sensitivity setting. Four detection
sensitivity levels are dip switch selectable from the front panel.
| Sensitivity |
-ΔL/L |
| Low | 0.32% |
| Med Lo | 0.16% |
| Med Hi | 0.08% |
| High | 0.02% |
Sensitivity Boost:
An external dip switch setting may be turned on to increase sensitivity during
the detect period. When a vehicle enters the loop, the detector sensitivity is
boosted to a higher level than the vacant loop setting. The boosted sensitivity
remains throughout the detect period. When the vehicle leaves the loop, the
sensitivity returns to the vacant loop setting. This feature helps prevent
dropouts during the passage of high bed vehicles and is particularly useful in
sliding gate situations.
Output Configurations: The output is selectable for "TruePresence™" ,
"Limited Presence" , "Pulse on Entry" , or "Pulse on Exit". TruePresence™
will hold the call for as long as the vehicle is present and power is not
removed or reset applied. Limited presence will typically hold the CALL output
for about 1-3 hours. The TruePresence™ time
applies only for normal size automobiles and trucks and for normal size loops
(approx. 12 sq. ft. to 120 sq. ft.). When in the pulse mode, the 250 millisecond
pulse can be selected as either pulse on entry (when a vehicle enters the
loop) or pulse on exit (when a vehicle exits the loop).
Call Delay: A 2-second delay can be activated by an internal dip switch. Output delay is
the time the detector outputs are delayed after a vehicle first enters the loop
detection area and is indicated by the front panel detect LED flashing at 4 Hz
with a 50% duty cycle. If the 2-second output delay feature is activated, the
output relays will only be turned on after 2 seconds has passed with a vehicle
continuously present in the loop detection area. If a vehicle leaves the loop
detection area during the 2-second delay interval, detection is aborted and the
next vehicle entering the loop detection area will initiate a new full 2-second
delay interval.
Output Call Memory:
When power is removed for 2 seconds or less, the detector automatically
"remembers" if a vehicle was present over the loop. When power is restored, the
detector will continue to output a call until the vehicle leaves the loop.
(Power loss or dips of 2 seconds or less will not drop the CALL).
Power Status Indicator: A green super-high-intensity light emitting diode (LED) indicates power status
during normal detector operation. When the green (PWR) LED is on, the power to
the detector is normal. When power drops approximately 20% from nominal, the
green LED turns off and the detector remains operational. When power drops
approximately 25% from nominal, the green LED is off and the "line" voltage is
not sufficient to operate the detector
Detect Status Indicator:
The red detect LED is steady on while a vehicle is being detected. The detect
LED will flash at a 4 Hz rate with a 50% duty cycle while timing out the
2-Second Call Delay.
Loop FAIL Monitor Indicator:
If the total inductance of the detector input network goes out of the range
specified for the detector or suddenly changes more than +/-25% the detector
will enter FAIL mode. The red FAIL
LED will either begin flashing with a 50% duty cycle once per second for a
shorted loop condition or will be on continuously for an open loop condition.
These indicator conditions will continue until the inductance returns to its
previous value at which time the detector output will automatically resume
normal operation, and the red FAIL LED will flash at a
distinctive rate (a burst of 3 flashes once per second) to indicate an
intermittent loop fault has occurred and corrected. The flash rate will continue
until another loop fault occurs, the detector is reset, or the detector loses
power. [The detector input network, consists of the loop or loops plus the
feeder cable (lead-in or home run) up to the connector on the detector].
Fail Safe Operation:
When the loop fails or power is removed, continuity exists between Common & N.O.
for presence mode. Continuity exists between Common & N.C. for pulse mode.
Fail Secure Operation:
When the loop fails or power is removed, continuity exists between Common & N.C.
for both presence and pulse modes.
Self Tuning:
Automatically tunes to loop within 2 seconds
after application of power or reset. 30 seconds of operation is required before
full sensitivity and presence time is reached following application of power or
a reset.
Environmental Tracking: Fully self-compensating for environmental changes and loop drift over the full
temperature range and the entire loop inductance range.
Loop Inductance Range: 20 to 1000 µh with Q factor of 5 or
greater.
Loop Feeder Length: Up to 2500 feet (762 m) maximum with proper feeder cable and appropriate loops.
Loop Input: Transformer isolated. The minimum capacitance added by the detector is 0.068 mF.
Grounded Loop Operation: The loop isolation transformer allows operation with poor quality loops (which
may include a single point short, or leakage, to ground).
Lightning Protection: The detector can tolerate, without damage, a 10
mF capacitor charged to 1,000
Volts being discharged directly into the loop input terminals, or a 10 mF
capacitor charged to 2,000 Volts being charged between either loop terminal and
earth ground.
Internal Circuitry Isolation:
All internal electronic circuitry is isolated from all external circuitry. Power
is isolated by means of the power transformer. The loop is isolated by means of
the loop isolation transformer. The outputs are isolated by means of the output
relays.
Automatic Reset Internal Fuse:
When 120VAC is applied to 24VAC models, the automatic internal fuse will open.
The fuse will automatically reset when power is removed for 3 seconds. Source
voltage should be verified before reinstalling.
Relay Rating(s):
The relay contacts
are rated for 6 Amp max, 150 VDC max, 300 VAC max and 180 Watts max switched
power.
Ruggedized Construction:
The enclosure is high temperature rated Lexan plastic. Printed circuit boards
are 0.062 in FR4 material with double sided 2-oz copper and plated
through-holes.
Operating Temperature: -40° F to + 180° F. Meets or exceeds NEMA specifications.
| Power(s): | Fuse(s): |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Size: 1.55 inches (3.90 cm.) Wide x 2.50 inches (6.35 cm.) High x 4.20 inches (10.65 cm.) Deep, including rear connector
Weight: Approx. 7.6 oz. (215.46 gm.).
Connector: 11 Pin Amphenol connector (86CP11)
|
Factory Default Settings
(External DIP Switch): |
Factory Default Settings
(Internal DIP Switch): True Presence™ (Infinite) 2-Second CALL Delay: OFF |
Models & Configurations |
|
|
Pin Assignments |
||
|
|
|
# |
Function |
||
|
Model |
Voltage |
Operation |
|
1 |
Power, Hot or (+) |
|
AX-3 |
120 VAC |
Fail Safe |
|
2 |
Power, Neutral or (-) |
|
AX-3-S |
120 VAC |
Fail Secure |
|
3 |
No Connection |
|
AX-7 |
24 VAC |
Fail Safe |
|
4 |
No Connection |
|
AX-7-S |
24 VAC |
Fail Secure |
|
5 |
Output, Common (Com.) |
|
AX-8 |
240 VAC |
Fail Safe |
|
6 |
Output, Normally Open (N.O) |
|
AX-8-S |
240 VAC |
Fail Secure |
|
7 |
Loop |
|
AX-23 |
12 VDC |
Fail Safe |
|
8 |
Loop |
|
AX-23-S |
12 VDC |
Fail Secure |
|
9 |
No Connection |
|
AX-24 |
24 VDC |
Fail Safe |
|
10 |
Output, Normally Closed (N.C.) |
|
AX-24-S |
24 VDC |
Fail Secure |
|
11 |
No Connection |
Note: Relay contacts are shown with power applied, loop(s) connected, and no vehicles present.
Notes: CALL Memory is always on. There is no switch
setting for this feature.
Please specify correct model number for FAIL-SAFE
or FAIL-SECURE when ordering
** Specifications are subject to change to reflect improvements and upgrades.
•